BR1600SI, Izlazna snaga 960 W, Tehnologija Line interactive AVR, Pure sinewave, Izlazni napon 230 V, Ulazni napon 230 V
APC BR1600SI
Back UPS Pro BR 1600VA, Sinewave,8 Outlets, AVR, LCD interface
High Performance Computer and Electronics UPS for Premium Power Protection
Technical Specifications
Output
Output power capacity: 960Watts / 1.6kVA
Max Configurable Power (Watts): 960Watts / 1.6kVA
Nominal Output Voltage: 230V
Output Frequency (sync to mains): 50/60 Hz +/-1 Hz
Topology: Line Interactive
Output Connections: (6) IEC 320 C13 (Battery Backup), (2) IEC 320 C13 (Surge Protection)
Input
Nominal Input Voltage: 230V
Input frequency: 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections: IEC-320 C14
Input voltage range for main operations: 176 – 294V
Maximum Input Current: 10.0A
Batteries & Runtime
Battery type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time: 16hour(s)
Expected Battery Life (years): 3 – 5
RBC Quantity: 1
Battery Volt-Amp-Hour Capacity: 260
Communications & Management
Interface Port(s): USB
Control panel: Multi-function LCD status and control console
Audible Alarm: Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Cold-start capable
Provides temporary battery power when the utility power is out.
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
PowerChute Personal Edition OS Compatibility
This software supports numerous operating systems and processors.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Sine wave output
Eliminates humming and heat generated when powering tube lights and fans
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)